Leak Tester Comparison V2

USON LEAK TESTERS

This leak tester comparison will compares all Uson leak testers and will  help you identify the best tester for your application.  Compare all of Uson’s electronic air leak and flow testing equipment by specification, channel operating modes, sensor types and more.  

 

Uson manufactures a variety of leak testing equipment for industries including Medical, Automotive, Electric Vehicles, Industrial and Packaging.  Compare all USON’s Leak Testers below to determine the right model for your application.  

Not sure which leak tester is right for your application?  We can help! Give us a call at 281-671-2000 or click here to email us and one of our leak testing experts will contact you.

628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Product
Industries Best Suited for Use
Industrial, Packaging, Medical
Industrial, Packaging, Medical
Industrial, Packaging, Medical, Automotive
Industrial, Packaging, Medical, Automotive
Industrial, Packaging, Medical, Automotive
Industrial, Packaging, Medical, Automotive
Images for Industrial, Packaging, Medical, Automotive
Max Channels Design
1
4
1
4
2
10
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Synchronus
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Independent
Check Mark
Check Mark
Check Mark
Check Mark
Coodinated
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Max Decision Sensors / tester
1
4
3
4
8
20
0 to 5 VDC max
Max Sensors / channel
1
1
2
2
4
2+1
A/D resolution (bits)
24
24
24
24
24
24
Max Analog Outputs / tester
1
1
1
2
10
0 to 10 VDC
Max Analog Outputs / channel
1
1
1
1
1
Analog Output bits
PWM (~12)
PWM (~12)
12
16
12
Pulse width modulation (PWM)
Maximum 24V DC discrete digital inputs / tester
11*
11
11
64
72
* requires PLC interface option
Valve Control signals / tester
18 (Internal)
16 (Internal)
18 (Internal)
12/channel
8/channel
Vector requires additional relays to drive valves (0.7A per output - 8A Maximum for Optima vT)
Maximum discrete digital outputs / tester
7
11 (not standard)
5
14
48
112
Discrete digital outputs / channel
8
2
5
12
12
8
Standard configurable digital I/O
Check Mark
Check Mark
Check Mark
Digital I/O Expansion option
N/A
8 in/16 out requires relays for valves
8 in/16 out (valve drive capable)
Additional 16 in 12 (valve drive capable) out (per TCU)
16 in/16 out 32 in/32 out and requires relays for valves
QmR requires additional PCB, vT requires Expanded I/O TCU2 Vector requires 1 or 2 addisional cPCI cards.
Two-handed start support (software based)
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Digital I/O Voltage Level
24 vdc
24 vdc
24 vdc
24 vdc
24 vdc
24 vdc
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Compressed Air
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Nitrogen
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Helium
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
RS-232 ports / tester
1
1
1
2
4
12
vT and Vector have 2 on main CPU, vT and Vector have one per channel. Channel ports currently not firmware implemented.
Host USB 2.0 ports
1
2
2
2
5
3
Device USB ports
1
1
-
-
-
Profibus
Check Mark
Check Mark
Check Mark
Check Mark
Modbus Serial
Check Mark
Check Mark
Check Mark
Check Mark
Modbus Ethernet
Check Mark
Ethernet IP
Check Mark
Check Mark
Check Mark
Check Mark
DeviceNet
Check Mark
Check Mark
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
RJ 45 Ethernet ports
1
1
1
2
2
Logging to a networked disk
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
iQ via FTP
Emailed alerts
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Size (H*W*D) Inches
5.3" X 12.6" X 13.2"
11 x 9 x 15
7 x 10.75 x 12
10.5" x 10" x 12"
*10 x 14 x 5
*14x22x20.5
* HMI Only
Weight lbs
22
18
24
15 - 22
15
65
Color Display size
4.3"
5.8"
8.5"
8.5"
15"
12.1"
Color Display Pixels
320 x 240
640 x 480
800 x 600
1024 x 768
800 x 600
Touch screen display
Check Mark
Check Mark
Check Mark
Touch scroll control pad
Check Mark
Check Mark
Front-panel membrane buttons
7
6
5
0
5
29
Front-panel run / program key
Check Mark
Check Mark
Check Mark
Check Mark
Front panel start/abort buttons
Check Mark
Check Mark
Check Mark
Check Mark
*
Check Mark
*vT uses touch screen
NEMA 12
Check Mark
Check Mark
Check Mark
Integrated pneumatics
Check Mark
Check Mark
Check Mark
Check Mark
Expandable pneumatics chassis
Check Mark
Remote pneumatics chassis
Check Mark
Check Mark
Test Ports
1
4
1
4
Custom
Custom
Calibration Ports
1
Combined With Test Ports
1
Combined With Test Ports
Custom
Custom
Test port style
-
1/8 NPT Female
1/8 NPT Female
1/8 NPT Female or 1/8 BSPP
Per Design
Per Design
Built-in AC or DC power supply
Check Mark
Pendant Style Remote Control
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Pressure
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Mass flow
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Differential pressure
Check Mark
Check Mark
Check Mark
Check Mark
Load cell
Check Mark
Check Mark
Check Mark
Laminar flow
Check Mark
Check Mark
LVDT
Check Mark
Check Mark
Electrical current
Check Mark
Check Mark
Electrical volts
Check Mark
Check Mark
Temperature
Check Mark
Check Mark
Check Mark
For the QMR the temperature input is exclusively for temperature compensation.
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Measure
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Pressure Decay with optional comp & optional cal from 0 to 1 500 psi
Check Mark
Check Mark
0 - 750 PSI
Check Mark
Check Mark
Mass Flow with optional comp & optional cal from 0 to 560 slpm
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
iQ limited to 20 slm, QmR limited to 20 slpm, vT/Vector limited to practicality
Laminar flow
Check Mark
Check Mark
Vacuum decay
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Pressure Increase Chamber Test
Check Mark
Check Mark
Check Mark
Sealed component test (a.k.a., Metered Chamber Test)
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Occlusion Test
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Burst under Pressure
Check Mark
Check Mark
Check Mark
Check Mark
Burst under Vacuum
Check Mark
Check Mark
Check Mark
Check Mark
Crack, upstream
Check Mark
Check Mark
Check Mark
Check Mark
Crack, downstream
Check Mark
Check Mark
Check Mark
Check Mark
Auto Zero
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Wait for input
Check Mark
Check Mark
Check Mark
Check Mark
Coarse Flow
Check Mark
Check Mark
Check Mark
Vacuum force decay
Check Mark
Check Mark
Check Mark
Differential Vacuum
Check Mark
Check Mark
Check Mark
Check Mark
Differential Pressure decay; 0 to 15 bar
Check Mark With Comp and Cal Standard
Check Mark
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Real time clock
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Program select via Digital Inputs
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Start / Abort via Digital inputs
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Bar code input & control
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
No tester control for Sprint iQ
Auto Comp & Auto Cal
Check Mark
Check Mark
Check Mark
Temp Comp (Pressure change)
Check Mark
Check Mark
Check Mark
Temp Comp (Temp change)
Check Mark
Check Mark
Q-DAS interface
Check Mark
Limited
Regulator – closed loop control
Fixed Algorithm based
*
PID with advanced options setup
Check Mark
Check Mark
Burst under Vacuum
Check Mark
Check Mark
Check Mark
Check Mark
In-field configuration
Check Mark
Check Mark
Configurable Pressure Units: psig, mbar, inH2O, mmH2O, inHg, mmHg, Kpa or Kg/cm2
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Parts Grading
Check Mark
Check Mark
Check Mark
Auto Run Mode
Check Mark
Check Mark
Check Mark
Check Mark
Conditional Program Jumps
Check Mark
Check Mark
Check Mark
Check Mark
Accept/ Reject Step Markers – Continuous with timeout
Check Mark
Check Mark
Check Mark
Check Mark
Accept/ Reject Step Markers - Pulsed
Check Mark
Check Mark
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Accept/ Reject / Total Counts
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Min/Max Test Result
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Average Pass/Reject Result
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Standard Deviation of all test results
Check Mark
Check Mark
Check Mark
Check Mark
Range of test results
Check Mark
Check Mark
Check Mark
Pressure versus time plot
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
628
Sprint iQ
Qualitek mR
Sprint mD
Optima vT
Vector
Notes
Operating System Software
Embedded Unix Based
Quadros RTOS
Unix Based
Unix Based
Unix Based
Windows XP
Run/Program security key
Check Mark
Check Mark
Password
Check Mark
Check Mark
Password protection
Check Mark
Check Mark
Check Mark
Check Mark
Check Mark
Hard Disk
Check Mark
Check Mark
Check Mark
R/W DVD (CD) option
Check Mark
Programs
30
99
99
127
199
TBD
Internal Test Result storage (test cycles)
500
250
1000
100,000+
100,000+
100,000+
Sequence
Program link. Stop control, Vent control, Delay time option, Step control
Program link. Stop control, Vent control, Delay time option, Step control
Program link. Stop control, Vent control, Delay time option, Step control
Jumps within a test, optional jumping and grading within a channel, conditional wait on input, math steps
Jumps within a test, optional jumping and grading within a channel, conditional wait on input
Sensor Calibration
Software zero & span.
Software zero & span with option of multi-point linearization per analog input.
Software zero & span with option of multi-point linearization per analog input.
Software zero & span with option of multi-point linearization per analog input.
Software zero & span with option of multi-point linearization per analog input.
Software zero & span.
Step Editing
Check Mark
Check Mark
Math Steps
Check Mark